Skip to content

EI30 and EI60 fire-rated doorsets for projects: classes, CE marking and documents

EI30 and EI60 are European fire-resistance classes under EN 13501-2: the doorset kept its integrity (E) and insulation (I) for 30 or 60 minutes in an EN 1634-1 test. EUROMEXA supplies fire-rated doorsets for projects against your door schedule; the quotation lists the manufacturer's classification report, test evidence and, where it applies, CE marking documents that come with the delivery. Quotation within 24–72 hours.

EUROMEXA is an independent supplier, not an authorised distributor or affiliate of any manufacturer named here; brand names identify compatibility only.

What do EI30 and EI60 mean?

In the European system a fire-resisting door is tested to EN 1634-1 and classified to EN 13501-2. The letters say which criteria the assembly met during the test, and the number says for how many minutes it met them.

CodeMeaning
EIntegrity: the doorset stops flames and hot gases passing to the unexposed side
IInsulation: the unexposed face stays below the temperature limits of the classification
I1 / I2The suffix shows which definition of insulation was used; a specification should say which one it requires
30, 60Minutes for which the criteria were met in the test (EI30, EI60)
CSelf-closing: the door closes by itself (with a number for the cycles tested)
SSmoke leakage limited (smoke control)

Doorset or door leaf: why the whole assembly matters

A fire classification belongs to the assembly that was tested — leaf, frame, ironmongery, glazing and seals — and to the variations its classification report covers. A door leaf on its own, or a doorset with hinges, locks or glazing outside that scope, does not carry the class.

That is why tenders ask for doorsets and why the ironmongery schedule is part of the quotation, not an afterthought.

CE marking in the EU: external and internal doorsets

  • External pedestrian doorsets with fire-resisting or smoke-control characteristics are covered by EN 16034, applied together with EN 14351-1. Since 1 November 2019 CE marking is the only route for them in the EU.
  • EN 14351-2 (internal pedestrian doorsets) is not in the European Commission's list of cited harmonised standards (list dated 9 February 2026), so internal fire doorsets are not CE marked under EN 16034; national rules of the destination apply.
  • Where CE marking applies, the manufacturer issues a Declaration of Performance (DoP) — under the new Construction Products Regulation (EU) 2024/3110, a Declaration of Performance and Conformity — before affixing the marking.
  • Regulation (EU) 2024/3110 entered into force on 7 January 2025 and replaces Regulation (EU) No 305/2011 product family by product family; check which applies to the doorsets on the date of supply.

The US route: UL 10C and NFPA 80

Tenders written to US practice ask for door assemblies tested to UL 10C (positive-pressure fire tests of swinging door assemblies) and installed and maintained to NFPA 80, Standard for Fire Doors and Other Opening Protectives. Ratings there are stated in minutes or hours, and the manufacturer's listing and label are the evidence.

If the specification names both a European class and a US rating, ask the engineer which one governs: they come from different test methods and are not interchangeable.

What the specification must state

  • The class required per door type (for example EI30-C or EI60-S, and EI1 or EI2), or the US rating
  • The standard route: EN 13501-2 / EN 1634-1, with CE marking where it applies, or UL 10C / NFPA 80
  • Single or double leaf, structural opening sizes, wall type and thickness
  • Glazing (size and position), vision panels, louvres and seals
  • Ironmongery schedule: hinges, locks, panic and exit devices, closers, hold-open devices, coordinators
  • Finish, colour and any acoustic or security requirement
  • Quantity per door type, delivery place and the required date

Documents EUROMEXA supplies with a delivery

The quotation states, line by line, which documents come with the delivery. They are the manufacturer's documents: EUROMEXA does not test, classify or certify doorsets.

DocumentWhat it shows
Classification report to EN 13501-2The class, the assembly it covers and its field of application; it names the laboratory that ran the test
Test report or test evidence to EN 1634-1 (or UL 10C)The test the classification rests on
Declaration of Performance and CE markingFor external pedestrian doorsets placed on the EU market under EN 16034 + EN 14351-1
Listing and label (US route)Where the specification asks for UL 10C / NFPA 80
Installation and maintenance instructionsHow the doorset must be fitted to keep its class
Commercial invoice, packing list, certificate of origin where applicableShipping and import documents from EUROMEXA

How EUROMEXA quotes a door schedule

  • EUROMEXA reads the door schedule and confirms, door type by door type, what it can supply and with which evidence
  • One quotation from EUROMEXA: price, lead time, Incoterm, and the class and standard of each door type
  • Clarifications to the tender are made in writing, through the official channel
  • Payment: first orders are paid in advance or with a deposit; credit terms are available for established accounts

Questions and answers

What is the difference between EI30 and EI60?
The minutes for which the doorset kept its integrity and insulation in the fire test: 30 or 60. Both are classes under EN 13501-2, from a test to EN 1634-1.
Are fire doors CE marked?
External pedestrian doorsets with fire-resisting characteristics are, under EN 16034 with EN 14351-1. EN 14351-2 for internal doorsets is not cited, so internal fire doorsets follow the destination's national rules.
Is a fire-rated door leaf enough?
No. The class belongs to the tested assembly — leaf, frame, ironmongery, glazing and seals — within the scope of its classification report.
Which documents should a tender ask for?
The classification report, the test evidence it rests on, the Declaration of Performance and CE marking where they apply, the US listing where that route is specified, and the installation instructions.
Does EUROMEXA test or certify the doorsets?
No. The classification, test and declaration documents are the manufacturer's. EUROMEXA supplies the doorsets and states in the quotation which of those documents come with the delivery.

Sources

  1. BSI (British Standards Institution): BS EN 13501-2:2023 — Fire classification of construction products and building elements, Part 2: classification using data from fire resistance and/or smoke control tests (Third party; checked 2026-11-17)
  2. Official Journal of the EU (reprint hosted by Buildwise): Commission Decision 2000/367/EC on the classification of fire resistance performance (OJ L 133, 6.6.2000) (Third party; checked 2026-11-17)
  3. BSI (British Standards Institution): BS EN 1634-1:2014+A1:2018 — Fire resistance test for door and shutter assemblies and openable windows (Third party; checked 2026-11-17)
  4. European Commission: Harmonised standards for construction products (CPR): summary of references (Third party; checked 2026-11-17)
  5. DIBt (German Institute for Building Technology): Closures with fire resisting and/or smoke control characteristics covered by a standard (Third party; checked 2026-11-17)
  6. European Commission: CE marking and Declaration of Performance and conformity (DoPC) (Third party; checked 2026-11-17)
  7. European Commission: Construction Products Regulation (CPR): overview (Third party; checked 2026-11-17)
  8. UL Standards & Engagement: UL 10C — Positive Pressure Fire Tests of Door Assemblies (Third party; checked 2026-11-17)
  9. NFPA: NFPA 80, Standard for Fire Doors and Other Opening Protectives (TIA 25-1, 2025 edition) (Third party; checked 2026-11-17)

Last checked 2026-11-17.

Request a quotation from EUROMEXA

Send the tender documents, bill of quantities or spares list, with the deadline. Within 24–72 hours you receive EUROMEXA's quotation — price, lead time, Incoterm and the standard each line meets — or a list of what is still needed. Partial information is fine to start. Nothing is ordered until you accept a written quotation.

Payment: first orders are paid in advance or with a deposit; credit terms are available for established accounts.